Kimo Temperature And Differential Pressure Transmitter CP 215

Product Specification for Kimo Temperature And Differential Pressure Transmitter, CP 215
Accuracy Range in Percent
0.5 of reading 2 mbar, (Pt100 temperature) : 0.5 % of reading 0.5 degreeC
Brand Name
Kimo View all products of Kimo
Display
19 digits 2 lines
Display Type
LCD
Frequency In Hz
50-60
Includes
LCC-S : configuration software with USB cable, SQR/3 function (square root for the measurement of air velocity and air flow), Calibration certificate, 115 Vac version transmitter, Connection tube, Connection fittings, Through-connections
Input Voltage (AC)
24 or 230, 115
Input Voltage in DC
24
Item Weight in grams
320 g
Material Type
ABS V0 as per UL94
Model
CP 215
Pressure Range
-2000/+2000 mbar
Product Information

Height of digits : Values : 10 mm ; Units : 5 mm
Pass-through : for cables 6 mm maximum
Cable gland : for cables 8 mm maximum
Output: 2 x 4-20 mA or 2 x 0-20 mA or 2 x 0-5 V or 2 x 0-10 V (4 wires), Common mode voltage <30 VAC, Maximum load : 500 Ohms (0/4-20 mA) / Minimum load : 1 K Ohms (0-5/10 V)
Galvanic isolation: Inputs and outputs (115 Vac/230 Vac models), Outputs (24 Vac/Vdc models)
Conditions of use (C/%RH/m): From -10 to +50 degreeC. In non-condensing condition. From 0 to 2000 m
Please always use the device in accordance with its intended use and within parameters described in the technical features in order not to compromise the protection ensured by the device.
Protection

IP65
Resolution

1 mbar ; 1 mmH2O ; 0.1 kPa ; 0.1 inWG ; 1 mmHG ; 1 hPa ; 1 daPa ; 0.1 PSI
Standards

European directives: 2004/108/EC EMC ; 2006/95/EC Low Voltage ; 2011/65/EU RoHS II ; 2012/19/EU WEEE
Storage Temperature in Celsius

-10 to +70
TSIN

T009190540
Warranty
No Warranty
Key Features

Units of measurement: mbar, mmH2O, kPa, inWG, mmHG, hPa, daPa, PSI, C / F
Device fully protected by double isolation or reinforced isolation
Electrical connection: Screw terminal block for cables 2.5 mm2 . Carried out according to the code of good practice
PC communication: USB-Mini Din cable
Environment: Air and neutral gases
Autozero: Manual by push-button
Type of fluid: Air and neutral gases
Security: Protection class 2 ; Pollution degree 2 ; Overvoltage category 2
Configurable intermediate ranges, Trend indicator
turn system mounting with wall-mount plate